Abstract

In CDQ (Coke Dry Quenching) shaft, the vent-cap with complex structure is installed in the cone-shaped funnel under the cooling chamber. It acts to introduce cooling gas and support the descending coke in the chamber. The designing and installation of vent-cap aim to get relatively uniform gas distribution, to reduce the temperature fluctuation of cokes at outlet and realize stable operation of CDQ apparatus. In this paper, the turbulent flow of gas in vent-cap of 1:7 scale CDQ experimental shaft is numerically simulated by using CFD (Computational Fluid Dynamics) software, CFX. The velocity field, the outlet flux distribution and the pressure drop factor of each outlet under three kinds of vent-cap (called high vent-cap, low vent-cap and elliptic vent-cap) are analysed and compared. The results turn out that the pressure drop factor of elliptic vent-cap is larger than the other two vent-caps, and that the pressure drop factors of high vent-cap and low vent-cap almost have the same value. While for a specified vent-cap, the pressure drop factor with pressing brick is larger than that without pressing brick. The work in this paper is valuable for the designing of vent-cap for large-scale CDQ shaft.