Abstract
We investigate the Ne-like Cr x-ray laser at 28.6nm by using a modified 1D lagrangian hydrodynamic code MED103 coupled with an atomic physics data package and a 2D ray tracing code as a post-processor. The laser pumping configuration includes two prepulses and one main pulse. The first prepulse normally irradiates the target, while the second prepulse and the main pulse irradiate the target at grazing-incident angles. We predict that saturation can be achieved for the Ne-like Cr x-ray lasers with a total pumping energy of 125mJ. Good beam qualities with no deflecting angle and a small divergence angle of 5mrad are observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.