Abstract

Three dimensional numerical simulations are performed on laminar heat transfer and fluid flow characteristics of a flat-plate channel with longitudinal vortex generators (LVGs). The effects of two different shaped LVGs, rectangular winglet pair (RWP) and delta winglet pair (DWP) with two different configurations, common-flow-down (CFD) and common-flow-up (CFU), are studied. The numerical results indicate that the application of LVGs effectively enhances heat transfer of the channel. According to the performance evaluation parameter, ( Nu/ Nu 0)/( f/ f 0), the channel with DWP has better overall performance than RWP; the CFD and CFU configurations of DWP have almost the same overall performance; the CFD configuration has a better overall performance than the CFU configuration for RWP. The basic mechanism of heat transfer enhancement by LVGs can be well described by the field synergy principle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call