Abstract

Helium flows at low pressure (3 bar) are used to cool the specimen capsules and the structure of the neutron irradiated High Flux Test Module (HFTM) of the DEMO-Oriented Neutron Source (DONES). The flow path includes inlet and outlet ducts with large cross sections, but also mini-channels with gap widths less than 1 mm, where a high velocity low Reynolds number flow influences the temperature of the irradiated specimens. The aim of the study was the achievement of thermal requirements to the HFTM. The large span of Reynolds numbers from laminar to fully turbulent is a significant challenge for the simulation of the complete HFTM. Several turbulence models were tested using experimental results obtained in the ITHEX (IFMIF Thermal-Hydraulic Experiment) experimental facility. Reynolds Stress (RSM) and k-ω Shear Stress Transport (SST) models are able to reproduce the heat transfer within the Reynolds number range between 4500 and 10,000.Simulations show that in case of 100% nuclear heating conditions the prescribed temperature of specimen can be achieved by justification of electrical power and variation of helium mass flow rate for each HFTM compartment.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.