Abstract

Changes to building codes that enable use of materials such as cross-laminated timber (CLT) in mid- and high-rise construction are facilitating sustainable urban development in various parts of the world. Keys to this are the transition to multi-performance-based design approaches along with fewer limitations on heights or the number of storeys in superstructures constructed from combustible materials. Architects and engineers have increased freedom to apply new design and construction concepts and methods, as well as to combine timber with other structural materials. They also have started to develop wall arrangements that optimise interior space layouts and take advantage of the unique characteristics of CLT. This paper discusses the seismic response of multi-story buildings braced with a CLT core and perimeter shear walls anchored to foundations and floor platforms using modern high-capacity angle brackets and hold-downs, or X-Rad connectors. Linear dynamic finite element (FE) models of seismic responses of superstructures of various heights are presented, based on experimentally determined characteristics of wall anchor connections. Particular attention is given to fundamental vibration periods, base shear and uplift forces on walls, as well as inter-story drift. Discussion of FE model results focuses on structural engineering implications and advantages of using CLT to create shear walls, with emphasis on how choice of wall anchoring connections impacts the possible number of storeys and configurations of superstructures. Employing CLT shear walls with X-Rad or other types of high capacity anchoring connections makes possible the creation of building superstructures having eight and potentially more storeys even in high seismicity regions. However, it is important to emphasise that proper selection of suitable arrangements of shear walls for CLT buildings depends on accurate representation of the semi-rigid behaviors of anchoring connections. The linear dynamic analyses presented here demonstrates the need during engineering seismic design practices to avoid use of FE or other design models which do not explicitly incorporate connection flexibilities while estimating parameters like fundamental periods, base shear and uplift forces, as well as inter-story drift.

Highlights

  • IntroductionIndustries are responding to the challenges and opportunities by developing suitable technologies for the renovation and construction of buildings, based on minimisation of lifecycle energy consumption and atmospheric carbon dioxide emissions [2]

  • Seismic actionsactions were calculated according to the Eurocode loads correspond to residential buildings

  • T1 * (= 0.05 H0.75 [35]), in Table 3 were calculated according to the simplified expression of Eurocode 8, as comparisons to T1,FEM determined from modal analyses (MA)

Read more

Summary

Introduction

Industries are responding to the challenges and opportunities by developing suitable technologies for the renovation and construction of buildings, based on minimisation of lifecycle energy consumption and atmospheric carbon dioxide emissions [2]. Using traditional and modern engineered wood products as structural materials offers advantages for renovation or construction of mid- and high-rise buildings. Wood-based products are widely regarded as carbon-neutral material choices, and their low density to mechanical property ratios make them highly suited for lightweight building superstructures [3]. Employing lightweight superstructures can minimise construction costs for superstructures themselves and the foundations on which they rest. They can increase architectural and structural engineering options in, for example, the design of relatively tall buildings in earthquake-prone regions

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.