Abstract

Numerical finite-element (FE) simulations and postprocessing analysis methods are presented for ultrasonic polar scan (UPS) measurements involving a circular phased array (C-PA) to determine the plane-wave reflection coefficient of plates. Apodization weights for the C-PA elements are determined to assure the generation of a quasi-plane wave upon excitation at the plate surface and to mitigate bounded beam effects on the assessed reflection coefficient. In addition, postprocessing of the reflection signals is performed via the synthetic plane-wave technique to further filter out any bounded beam effects. Reflection coefficients are presented for three cases namely, an aluminum, a unidirectional carbon epoxy, and a cross-ply carbon epoxy plate. For all three cases, comparison with the analytical plane-wave theory shows excellent agreement with the reflection coefficients obtained by the C-PA and the additional postprocessing steps for both the pulsed and harmonic signals. It is also shown that the agreement becomes considerably worse if the nonspecular reflection field is disregarded in the postprocessing treatment, thus enforcing the need to capture the full reflected field via the PA whenever plane-wave reflection coefficients are needed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.