Abstract
Vapour compression refrigeration is the most widely used method in domestic and commercial air conditioning and refrigeration systems. R22 (difluoromonochloromethane) is the most widely used HCFC (hydro chlorofluorocarbon) refrigerant in residential, commercial, industrial and transport cooling systems. Montreal protocol in 1987 banned the use of CFCs (chlorofluorocarbon) due to their adverse impact on the environment causing ozone depletion and global warming. HCFCs are also being phased out, though they are less destructive than CFCs. The present work explores compressor performance using alternate environment friendly working fluids so that R22 can be replaced in future. The refrigerants used for the studies are R134a (tetrafluoroethane), R290 (propane) and R600a (isobutane). Compressor performance is analysed by varying refrigerant mass flow rate, evaporator and condenser temperatures and studying their effect on compressor size, power and discharge temperature. A numerical simulation code has been developed in MATLAB using refrigerant properties taken from REFPROP.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.