Abstract

A three-dimensional numerical approach incorporating the radiation, solar load, and turbine models proposed in this paper was first verified by the experimental data of the Spanish prototype. It then was used to investigate the effects of solar radiation, turbine pressure drop, and ambient temperature on system performance in detail. Simulation results reveal that the radiation model is essential in preventing the overestimation of energy absorbed by the solar chimney power plant (SCPP). The predictions of the maximum turbine pressure drop with the radiation model are more consistent with the experimental data than those neglecting the radiation heat transfer inside the collector. In addition, the variation of ambient temperature has little impact on air temperature rise despite its evident effect on air velocity. The power output of the SCPP within the common diurnal temperature range was also found to be insensitive to ambient temperature.