Abstract
Based on the heat transfer and flow resistance of diesel locomotive radiator, the influence was studied about the cooling air inlet speed on heat transfer coefficient and pressure loss of finned tube double channel radiator with louver by using CFD method. Temperature field, speed field and pressure field distribution of radiator calculation results were analyzed. The radiator was tested at different cooling air inlet speed, compared test results with simulation results, the greatest relative error of the heat transfer coefficient and pressure loss were 7.21% and 7.72%, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.