Abstract

Limestone of different particle sizes is often calcined together to improve production efficiency, but the calcination effect of mixed particle size limestone is difficult to guarantee. To investigate the effect of different particle size combinations on calcination, this study uses a porous media model and a shrinking core model to simulate the calcination process for a single particle size and two mixed particle sizes in a Parallel Flow Regenerative lime kiln (PFR lime kiln). The results of the study show that an increase in void fraction has a small effect on the gas temperature. The temperature also does not change with particle sizes. At the same time, the decomposition is poor near the wall and better the closer to the center of the calcination zone. In addition, when the particle sizes differ by 2 times, the decomposition of small limestone particles had less influence, and the decomposition of large particles was also better. When the particle sizes differ by 3 times, the decomposition of both limestone sizes is more affected, especially for the larger limestone size, where only the outer surface is involved in the decomposition.