Abstract
Dimethyldichlorosilane hydrolysis devices are now faced with problems of incomplete reaction and emulsion between the mixture of siloxane and the hydrochloric acid. This paper adopted ideas of falling film and designed a inclined plate to avoid the problems. CFD software was used to simulate the water-oil falling film on the plate.The simulation results show that using a inclined plate within the reactor can expand the contact area between water and oil effectively. The hydrolysis reaction is completed and there is no emulsified phenomenon happening by using the plate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.