Abstract

Abstract Laboratory and field measurements of soil suction using a thermal conductivity soil suction sensor involves installing the sensors into a soil mass. The sensors may be installed either in an initially wet or an initially dry state. In order to ensure a reliable suction measurement, it is important that the sensor reach suction equalization with the surrounding soil. The results of a numerical study have shown that, in most cases, the equalization time required for an initially dry sensor is less than the equalization time for an initially wet sensor. This difference is mainly due to the unsaturated zone that develops on the boundary of the initially wet sensor at the beginning of the drying process. The results of the numerical simulation have been substantiated by laboratory suction measurements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.