Abstract

In this paper, based on the theoretical analysis and reasonable simplification, one-dimensional mathematical model is presented for the counter-current oxidation of ventilation air methane. The process of counter-current oxidation reaction is simulated by applying the computational fluid dynamics (CFD) software (Fluent), and the effect of the dominating working parameters (such as flow velocity and equivalence ratio and half cycle) are discussed on the temperature and rate of reaction within the counter-current oxidation reaction. The distribution of the temperature field and the reaction rate are simulated when half cycle is 30s, the equivalence ratio is 0.2 and the velocity 0.06 m/s, 0.1m/s and 0.2 m/s. The combustion characteristics are summarized for the device of counter-current oxidation reaction, and the effects of working parameters are analyzed on the burning characteristics. It is so important to increase the combustion efficiency and energy utilization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.