Abstract

A numerical simulation was performed to clarify renal blood flow determination by the vascular structures. Large and small vessels were modeled as symmetric and asymmetric branching vessels, respectively, with simple geometries to parameterize the vascular structures. Modeling individual vessels as straight pipes, Murray's law was used to determine the vessel diameters. Blood flow in the vascular structure was calculated by network analysis based on Hagen-Poiseuille's law. Blood flow simulations for a vascular network segment demonstrated that blood flow rate and pressure vary within the same-generation vessels because of an asymmetric vessel branch while they generally tend to decrease with vessel diameter; thus, the standard deviation of flow rate relative to the mean (relative standard deviation [RSD]) increased from 0.4 to 1.0 when the number of the daughter vessels increased from 3 to 10. Blood flow simulations for an entire vascular network of a kidney showed that the vessel number and branching style, rather than Strahler order, are major parameters in successfully reproducing renal blood flow measured in published experiments. The entire vascular network could generate variation in the physiological flow rate in afferent arterioles at 0.2–0.38 in RSD, which is at least compatible with 0.16 by diameter variation within the same-generation vessels.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call