Abstract

The present study investigates the heat transfer characteristics of a U-shaped vertical closed-loop thermosyphon filled with a phase change material (PCM) suspension using numerical simulation. The loop is made of a copper pipe (outer diameter/inner diameter=1.46). The heating section and the cooling section are located at the bottom and top of the loop, respectively, and octadecane is used as the PCM. Parametric simulations were conducted using the pertinent physical parameters of a loop with a fixed geometrical configuration with the following parameter ranges: modified Rayleigh number Ra∗=5×103-5×105, modified Stefan number Ste∗=0.05-5, PCM suspension concentration fp=0–10%, PCM particle dimensionless diameter Dp=0.23–0.0023, and modified subcooling factor Sc∗=0.2-1.0. The results show that Ste∗ presents a critical value under the given parametric conditions; when Ste∗ is less than the critical value, the latent heat effect becomes significant, and the temperatures in the heating and adiabatic sections of the loop decrease considerably.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call