Abstract

In order to analyze the effect of the air volume on the combustion side and the non-uniformity of pulverized coal on the temperature distribution of the boiler outlet flue gas, and then analyze the thermal deviation characteristics of the steam heating surface, the following five different working conditions are calculated and analyzed in a 660MW boiler. Results show that the deviation of pulverized coal content of each burner and the deviation of primary air volume are the important factors that cause the temperature deviation of flue gas outlet in the furnace. Therefore, it is an important way to improve the temperature distribution and reduce the thermal deviation of flue gas outlet by improving the uniform combustion and air distribution of the burner in the furnace.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.