Abstract

The flow, radiation intensity and concentration of microorganisms in three UV reactors are simulated using an integrated mathematical model for UV disinfection. All governing equations are solved using the commercial CFD software ANSYS Fluent. The effect of internal configuration on the disinfection level in the reactor is discussed in detail. There exists a relatively strong recirculation in the lower part of the U-type reactor. The two baffled reactors improve the mixing of microorganisms. The longitudinal baffled reactor can achieve the highest disinfection level. It is recommended that the arrangement of baffle should produce a longer flow path.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.