The freeboard, which is an important region in COREX melter gasifier, has drawn more and more attentions, and as a key parameter for COREX melter gasifier operation, the temperature in freeboard must be within a certain range. In this paper, the temperature field of freeboard is simulated with computational fluid dynamics(CFD). The results show that the temperature in bottom is lower than that in upper. The temperature when oxygen nozzles are open is higher than that when oxygen nozzles are off, and the temperature under different operation conditions is all about 1000 °C.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.