Abstract

Investigation of the combustion of the coal-dust flame in a BKZ-75 boiler furnace of the Shakhtinskaya thermal power station (TPS) is carried out using three-dimensional simulation. The distributions of the full velocity vector and the temperature and components concentration profiles, including hazardous pollutants, in the furnace volume and at its outlet are determined. It is shown that swirling flows of the airfuel mixture that enters the furnace through contradirectional burners form a volume vortex flow in the central section. The maximum concentrations of combustion products in the area of arrangement of burner devices are observed in the cross section of the body of the flame. The concentrations of hazardous pollutants at the furnace outlet are less than the admissible concentrations accepted for the TPS.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.