Abstract

To enhance the exhaust efficiency during ventilation, three types of air duct outlets were imported. According to the characteristics of velocity distribution simulated by numerical method, the flow field is divided into the mixing zone and the exhaust zone. The gradual contracted air duct outlet can enhance the mixing effect between fresh air and smoke. In the exhaust zone, however, the flow velocity on the upper section of the tunnel is weakened, which is unfavorable for smoke exhaust. Gradual expanded air duct outlet, on the contrary, may weaken the concentration effect of the airflow. The flow velocity on the upper section of the tunnel is increased in the exhaust zone, thus the flow field is more homogenized, which is in favor of smoke exhaust.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.