Abstract

In this work, we present a theoretical analysis of diffusion processes at arrays of recessed microelectrodes and evaluate the dependence of these processes on the main geometrical parameters (distance between electrodes in the array and slope of side walls of conical recesses) of this complex system. To allow for faster computation time and excellent accuracy, numerical simulations were performed upon transforming the real space allowed for diffusion using a quasi-conformal mapping introduced for this array geometry in our previous work (Amatore, C., Oleinick, A. I. and Svir, I. J. Electroanal. Chem. 2006, 597, 77-85). The applied quasi-conformal mapping is perfectly suited to the considered microelectrode array geometry and ensures that the abrupt change of boundary conditions reflecting the contorted geometries of the considered microelectrode array are treated efficiently and precisely in the simulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.