Abstract

To predict three-dimensional temperature distribution of molten aluminum and its influencing factors inside an industrial aluminum holding furnace, a fluid-solid coupled method was presented. The fluid-solid coupled mathematics models of aluminum holding furnace in the premixed combustion processing were established based on mass conservation, moment conservation, momentum conservation, energy conservation and chemistry species conservation. Computational results agree well with the test data of the typical condition. The maximum combustion temperature is 1 850 K. The average temperature of the molten aluminum is 1 158 K, and the maximum temperature difference is about 240 K. The average temperature increases 0.3 °C while the temperature of combustion air increases 1 °C. The optimal excess air ratio is 1.25–1.30.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.