Abstract
Wet rotating reticular plate electrostatic precipitator gathers the advantages of moving electrode type electrostatic precipitator technology and wet electrostatic precipitator technology, and utilizes reticular plate, which significantly increases the dust collecting area. In this paper, airflow distribution boards were simplified as porous jump model, and empirical equation was used to get the inertial resistance factors of airflow distribution boards. FLUENT was used to simulate the internal flow field under the condition of without guide plates and with guide plates. Regular skewed airflow was formed through introducing guide plates, which improved the internal flow field significantly.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.