Abstract
This work focuses on methods of submersible sewage mixer performance evaluation comparison. In the paper an experiment with a submersible mixer with a published and known geometry has been presented. The authors measured thrust, torque rotation speed and electric power. Experiment was compared with results obtained with a steady state numerical simulation. Next CFD results were checked with a theoretical approach for the mixing range. Both theoretical and numerical methods showed good applicability for the industry.