Abstract

The load distribution among piles in a group varies such that the inner piles often carry a smaller share of the total load compared to the outer piles, which is a result of increased soil–pile interaction. The main objective of this paper is to establish the relative effectiveness of pile groups with no inner piles (perimeter group), when compared to the more common grid configuration. The numerical investigation utilized the finite element programme ABAQUS and considered a range of variables that affect pile group behaviour including number of piles, pile spacing, length/diameter ratio, and soil strength. It was demonstrated that a complete grid group is less efficient than a perimeter group, where efficiency is defined as the load capacity of the whole group expressed as a ratio of the number of piles in the group multiplied by the load capacity of a single isolated pile. Efficiencies close to unity were observed for some perimeter groups. Perimeter groups also showed that a “block” type group failure could occur, where piles were placed at a spacing of less than 2.0 pile diameters,d, centre-to-centre. This often, but not always, led to a reduction in the efficiency of the pile group.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.