Abstract
The five-layer nanorod-mediated surface plasmon sensor with inhomogeneous liquid crystal layer was theoretically investigated. The reflectance as the function of the incident angle was calculated at different voltages applied to the liquid crystal (LC) for different analyte refractive indices. By changing the LC director orientation one can control the position of the reflective dips and choose the one that is the most sensitive to the analyte refractive index. At the chosen angle of incidence, the analyte refractive index can be found from the reflectance value. The director reorientation effect is stronger when the prism refractive index is between ordinary and extraordinary refractive indices of the LC. In this case, the voltage increase and the prism refractive index decrease have a similar effect on the reflectance features.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.