Abstract

The article is devoted to studying the parameters of wells that are used as part of vertical landfill gas collection systems for degassing landfills. To this end, the thermophysical model developed in the first part of this work is considered. The model is constructed using the initial data obtained at real dump and landfill with subsequently comparing the calculation results with the data of experimental measurements. A method for determining the average hydrodynamic properties of wastes is proposed, using which the heterogeneity of wastes can be taken into account. The effect the operating and design parameters of the well have on its performance is investigated on the basis of these properties. It has been determined that increasing the suction pressure, drilling diameter, and perforation height allows the well production rate to be increased by around 10%. The effect the increase of the well production rate has on the landfill gas collection project’s payback period is demonstrated taking typical dump and landfill as an example.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.