Abstract
Brazing of galvanized steel causes decaying of the zinc coating and decreasing of corrosion resistant on heataffected zone (HAZ) and weldment. The corrosion rates among the HAZ, unaffected base metal (UBM), and weldment of galvanized steel welded by brazing were numerically modeled by COMSOL Multiphysics. The numerically modeled current density values from various zones, such as the couples between the HAZ and the UBM, between the weldment and the HAZ, and between the UBM and steel were used to calculate the corrosion rates. In this work, two different methods based on Faraday’s Law, the mixed potential theory and the Numerical modeling, were compared for calculations of the corrosion rates of each region. Using the mixed potential theory, the calculated corrosion rates of region I, II, III, IV, V and VI were 0.853, 0.284, 2.105,1.754, 2.028 and 0.554 mm/y, respectively. Where as based on the Numerical modeling, these rates of all regions were 0.918, 0.275, 2.198, 1.904, 2.151, and 0.566 mm/y, in orderly. These comparisons suggested that the corrosion rates obtained from two methods were similar. However, the results showed that the Numerical modeling method could predict the corrosion rate with less error.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.