Abstract

Numerical simulations for a T-pipe consisting of a rectangular duct for main stream and a circular pipe for branch stream were performed to investigate relation between large-scale eddy structure formation in the mixing area and temperature fluctuation generation on the wall. Moreover, the numerical simulation to investigate thermal interaction between fluid and structure were conducted. Experimental results of temperatures at 2mm from the wall in fluid, on the wall and at 3mm inside from the wall in structure were compared with those of the numerical results. The numerical results indicate that the fluid-structure thermal interaction is necessarily considered for thermal fatigue estimation in the thermal striping phenomena.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.