Abstract
By simulating two types of the contactless methods for measuring the critical current density, the resolution of the crack detection in a high-temperature superconducting (HTS) film has been investigated. To this end, a numerical code has been developed for analyzing the shielding current density in an HTS film with a crack. By using the code, the scanning permanent magnet method and the inductive one have been reproduced numerically. The results of computations show that the scanning permanent magnet method shows a relatively poor accuracy for the crack detection. If the inductive method is applied to the region obtained by the scanning method, the detection accuracy of the crack is drastically improved. The crack can be detected with high speed and high accuracy by combining the inductive method and the scanning method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.