Abstract

A numerical investigation was conducted to study the role of rebar mesh on the electrical resistivity measurements of concrete using the Wenner probe technique. The effects of rebar spacing, cover thickness, the location of the Wenner probe with respect to the rebar mesh, and slab thickness were investigated. The results revealed that current guidelines for taking resistivity measurements over rebar mesh do not necessarily provide the most accurate results. As much as 30 % increase in accuracy can be achieved just by selecting appropriate orientation or location for the Wenner probe. Having the probe placed parallel to the top rebars midway between both top and bottom bars was found to be the most suitable arrangement to minimize the rebar mesh interference on the electrical resistivity measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.