Abstract
This paper presents a numerical study of detailed heat transfer and flow field characteristics in a flat plate heat exchanger with different types of ribs (rectangular and triangular) with different heights (H: 2.5, 5, 7.5, and 10 mm) and spacings (S: 75, 95, 128, and 195 mm). A comprehensive numerical model was established and validated with experimental data in the literature, resulting in good agreement. The effects of the height, spacing, and shape of the ribs in addition to thermal-hydraulic parameters were investigated over two values of the Reynolds number (9880–3210). The results concluded that the highest values of the thermal-hydraulic parameters are 1.62 and 1.84 for the hot and cold air sides, in the rectangular ribs, with a thickness, height, and spacing of 75 mm, and 95 mm, respectively. It is worth mentioning that the rectangular ribs have the maximum value of thermal performance at the high and low values of the Reynolds number of turbulent flows. The present design can be used in waste heat recovery systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.