Abstract

Vaned diffuser inlet flow uniform is challenging when the impeller is throttled to stall. In this study, we extend the stable operating range of the compressor by improving the uniform flow of the diffuser inlet. First, a numerical investigation of a transonic centrifugal compressor with a vaned diffuser is presented and compared against test data. Then, a new diffuser parameterization method is pro- posed, and the throat feature of a pipe diffuser is successfully applied to parameterized vane diffusers. The influence of the throat length and divergence angle of the diffuser on the performance of the centrifugal compressor is studied via steady and non-linear harmonic simulations. Throat length delays the time of fluid pressurization and accommodates large flow instabilities from upstream—this widens the stall margin but increases mixing loss. Divergence angle affects compressor performance. Stage peak efficiency increases by about 0.58% as the divergence angle increases from 3.79° to 5.79° but drops to about 2.46% as the divergence angle further increases from 5.79° to 11.79°. This is because the boundary layers in the diffuser channel thicken with increasing divergence angle; additionally, the fluid near the hub-pressure side first becomes unstable, then flow separation occurs along the flow direction, which results in a large flow loss. Detailed performance maps of centrifugal compressors with different throat lengths and divergence angles are given to provide a reference for designing transonic centrifugal compressors.