Abstract

BackgroundIn the present study, a parallel microchannel system is attached to the battery pack to decrease the temperature of the plate that the battery pack install on it. In fact, battery cooling is critical for electronic devices as the increasing temperature has a negative effect on performance. MethodsThe impacts of several parameters like Reynolds number, and volume fraction of nanofluid are investigated on the battery surface. Significant findingsThe numerical results demonstrated that the temperature of the battery surface declines dramatically up to 4° as the Reynolds number increases. Moreover, the increasing volume fraction of the present nanofluid to 0.1% boosts the heat transfer up to 12.1% and decreases the thermal and viscous entropy generations up to 5.37% and 23.2%, respectively. However, increasing the Reynolds number from 400 to 2200 resulted in a 253.71% and 389.80% increase in the thermal viscous generations. optimization revealed that the best channel number is 39 in which the Nusselt number and pressure ratio intensified by 17% and 24%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.