Abstract

A combined impingement-pedestal geometry for turbomachinery double wall cooling application is studied numerically with the shear stress transport turbulence model. Conjugated CFD simulation is performed to investigate the cooling effectiveness distribution. The configuration consists of a high aspect ratio cooling duct, with jet array impinging onto the pin fin-roughed wall. The jet Reynolds number varies from 8,000 to 80,000, jet-to-target wall spacing is kept constant at Z/Dj=0.8. Three main parameters are investigated, including the jet Reynolds number, pin fin shapes (circular and elongated) and the relative location between jets and pin fins (the jet placed uniformly inside the duct or more densely at the front of the duct). For more detailed investigations, the pin fin diameter and impingement hole diameter are varied independently, and a total of 26 configurations are studied. The results show that the double wall configuration with pin fins significantly increases the heat transfer coefficients, compared to that with only impingement. Non-uniform jet arrangement results in a stronger crossflow and enhances heat transfer on the pins, which brings an increase of cooling effectiveness and more uniform temperature distribution.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call