Abstract

A Kretschmann-type surface plasmon resonance waveguide sensor is analyzed using the wide-angle beam- propagation method (BPM) with the complex Pade approximant and the finite-difference time-domain (FDTD) methods based on the recursive convolution (RC) and piecewise linear RC (PLRC) techniques. The wavelength responses of the sensor are calculated, and a detailed comparison of the numerical results is made. The BPM results are validated through a comparison with the FDTD results, in which the PLRC technique is required in terms of accuracy. The waveguide sensor shows a maximum absorption wavelength shift from 0.609 to 0.623 mum, as the refractive index of an analyte is increased from 1.330 to 1.334, which is comparable to the sensitivity of the conventional Kretschmann configuration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.