Abstract

The structure of an air cored high voltage pulse transformer is relatively simple, but considerable attention is needed to prevent breakdown between transformer windings. Since the thickness of the windings in spiral strip type is on the order of sub-millimeter, field enhancement at the edge of the windings is very high. It is, therefore, important to find proper electrical insulation parameter to make the system compact. Several shapes of the winding are considered and are analyzed by numerical field simulations to find an optimum transformer design parameter. Two design parameters are considered in the numerical simulation. Those are radius of the tip and radius of the edge in the transformer. The several dielectric insulation materials also are analyzed numerically to find out the field grading in the windings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.