Abstract

The numerical tests of the optimized high drainage roadway location in a fully mechanized coal face were conducted with different vertical distances and horizontal distances. The results show that higher vertical distance of high drainage roadway is beneficial for upper corner safety and gas control, and the optimal vertical distance of the high drainage roadway in the studied coal face is 30m-45m, and the best horizontal distance is about 30m.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.