A 450 kW segmented arc heater facility is designed and its performance is analyzed using a computational code named ARCFLO4. The constrictor length is set to 46.2 cm, which allows a proper constrictor diameter and a nozzle throat diameter of 1.4 and 1.2 cm, respectively, considering the stability of arc discharge. It is shown that the calculated mass-averaged enthalpy values are within the range from 12.3 to . The ratio of the centerline enthalpy to the mass-averaged enthalpy in the nozzle throat region is about 1.22, which signifies a fairly uniform total enthalpy distribution. The wall heat fluxes are also calculated to provide the information needed for designing the cooling system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.