Abstract

Air-water CCFL (countercurrent flow limitation) tests using the 1/5th scale rectangular channel and 1/15th scale circular tube simulating a PWR hot leg and both air-water and steam-water CCFL tests using the 1/3rd scale rectangular channel were previously carried out at Kobe University and Forschungszentrum Dresden-Rossendorf (FZD), respectively. In this paper, numerical calculations for the air-water CCFL tests at FZD using FLUENT6.3.26 are presented and compared with the experimental data at Kobe University and FZD. In the calculations, the VOF (volume of fluid) model or two-fluid (2F) model was used. Major results were as follows: (1) the calculated CCFL characteristics using the 2F model for the FZD tests agreed well with the 1/15th scale circular tube data obtained at Kobe University and the calculated results for full-scale PWR conditions, which supported the validity of the 1/3rd scale rectangular channel to simulate CCFL in circular tubes; and (2) comparison with the FZD data showed that the calculations using the 2F and VOF models overestimated the falling water flow rates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.