Abstract

AbstractA numerical valve model has been validated to predict the discharge capacity in accordance to the requirements of valve sizing method EN ISO 4126‐1 and the opening characteristic of high‐pressure safety valves. The valve is modeled with computational fluid dynamics software ANSYS CFX, and the model is extended with the Soave‐ Redlich–Kwong real‐gas equation of state to allow calculations at pressures up to 3600 bar. A unique test facility has been constructed to perform valve function and capacity tests at operating pressures up to 600 bar with water and nitrogen. For gas flows, the numerical results and the experimental data on mass flow rates agree within 3%, whereas deviations in flow force are 12% on average. The inclusion of fluid‐structure interaction in the numerical method improves the results for the flow force well and also gives insight into the valve dynamics of an opening safety valve. In a comparison between the experimentally and numerically determined liquid mass flow rates, a model extension accounting for cavitation reduces overpredictions by a factor of 2–20% for smaller disk lifts and decreases the deviations in flow force from 35 to 7%. At higher disk lifts, the effect of cavitation is less, and experimental and numerical mass flow rates agree within 4% and flow forces within 5%. © 2011 American Institute of Chemical Engineers AIChE J, 2011

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.