Abstract

This work presents research concerning the numerical assessment of two previously measured temperatures due to firebrand accumulation on surfaces, which was determined in former thermal experimental campaigns. A 3D numerical model using thermal transient non-linear analysis is used to validate the thermal outputs of these two previous experimental campaigns, and therefore, corroborating the previous temperature vs. time curves created with a prescribed flux in the firebrand accumulation area. The firebrand thermal heat transfer to the plane surface is simulated using convection and radiation film conditions, in which a 3D non-linear, time-dependent finite element simulation is used. Then, the previous proposed standard firebrand accumulation curve, ISO 834, and external fire curve are numerically compared with the results from previous firebrand accumulation curves in a wood corner wall. Finally, the merit assessment of the proposed standard firebrand accumulation curve shows a visible improvement, which has low values and is in accordance with the experimental results in the temperature field distribution of firebrand accumulation onto a contact surface. It is fair to argue that it constitutes a point to search for an efficient design for structures at elevated temperatures due to firebrand accumulation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call