Abstract

This paper presents experimental data measured in a bed of gypsum boards in the transient moisture transfer (TMT) facility at the University of Saskatchewan. The relative humidity and temperature were measured at two depths in a gypsum bed and the moisture accumulation was measured for the entire bed. Experiments were conducted for both coated (acrylic and latex paint) and uncoated gypsum. These experimental data are compared to simulated data from eight different numerical models. The agreement between the experimental and numerical data is good and often within the experimental uncertainty bounds. A sensitivity analysis was performed to show the influence of material properties such as sorption, vapour permeability and the transfer coefficients on the simulated results. One model examines hysteresis of the sorption isotherm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.