Abstract

In this paper, performance of centrifugal pump as turbine (PAT) is investigated numerically. Three different specific speeds are considered and three pumps are designed using diagrams from catalogues and CFturbo V.9 software. Next, models are analyzed by Ansys CFX 16 software and results are compared with those of CFturbo software. Also, a mesh study analysis for one case is performed in order to show the effect of grid size on the solution. In addition, three different flow rates of 75%, 100%, and 125% of best efficiency point (BEP) are considered for extracting head-flow rate diagrams and comparing results of CFX and CFturbo software. In next step, using relations between pump and turbine modes (PAT formulations) and by changing boundary conditions in CFX, turbine mode is investigated and efficiency is compared with pump mode. Finally, by an economic analysis a comparison between PATs and turbines with same nominal output powers are performed to distinguish which case is more profitable. Results showed that PATs have lower payback time in comparison with turbines with equal output power (in low capacities), although they have lower efficiencies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.