Abstract
The heat transfer, friction and exergy loss of a square duct with combined circular and trun-cated rectangular ribs are analyzed using computational fluid dynamics. The study is focused on the effect of rib arrangements on the flow and heat transfer performance. The analysis is carried out with six truncated rib angles varying between 15° and 90° and Re range of 12000 – 43000. The heat transfer is maximum in the middle part of the duct for 30° and 45° rib angles along span wise direction. The position of wake region is highly dependent on separation point over the circular rib as wake moves away radially from the axis of the duct for rib angles of 60°, 75° and 90°. The turbulent flow structures in large scale originates from side wall have marked effect on the heat transfer for the rib angles of 60°, 75° and 90° and with nearly with equal intensity for 15°, 30° and 45° rib angles. The exergy loss associated with friction is higher for 60° rib angle. While the normalized friction factor obtained with Fanning’s equation varied between 1.8 and 4.2 and thermal hydraulic performance varied between 0.2 and 1.3 for the range of reexamined.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.