Abstract

This article deals with the investigation of wind effects on a façade of a rectangular residential building with explicit modelling of the windows for specific wind conditions. The external wind pressure coefficients were treated on the façade and at the places of the window sills, linings, and lintel for the direction of the wind from 0° to 90° with increments of 22.5°. For a detailed analysis, the CFD simulation using Ansys Fluent was used. The method selected for the CFD simulation solution and its setting (quality of meshing, horizontal homogeneity of the boundary layer, etc.) were verified by known results of similar objects. The purpose of this analysis is to show how important it is to consider wind effects to determine the suitable placement of passive ventilation devices. Research shows the potential optimal position of ventilation units in terms of favourable pressure distribution. Zones with negative pressure and corners or façades in a wake are not suitable for applying passive ventilation units. The results can serve as a basis for designers to achieve optimal comfort in residential buildings.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call