Abstract
Analysis on steady-state and transient heat transfer on a flat plate at the middle of a parallel duct immersed in He II was performed for bath temperatures from 1.8 to 2.1 K at 101.3 kPa. Two-dimensional computer code named SUPER-2D developed by the authors based on the two-fluid model and the theory of mutual friction was used. Steady-state critical heat flux (CHF) and the time lag from the application of a step heat input to λ transition, that is called a lifetime, were obtained numerically for various step heat fluxes and for the channel gaps from 2 to 20 mm. Effect of the gap restriction on the CHF and the lifetime were clarified. The solutions were compared with the experimental data for the ducts with the same structures and the corresponding conditions. They agreed well with the experimental data. The heat transport mechanism in the parallel duct was clarified.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.