Abstract

By establishing a 3D finite element numerical simulation analysis model of railway-soil-trench-building, the accuracy of the simulation analysis model is verified using on-site measured data of surface vibration attenuation law. Install vibration isolation trenches with different depths at different locations between the building and the railway, and analyze and compare the impact of indoor vibration in different situations. The results indicate that; The surface vibration caused by railways attenuates rapidly around 30m~76m from the line, and then shows a slight amplification trend around 120m. The surface vibration near the railway is mainly concentrated in the range of 15-90Hz; The vibration reduction effect of trench on different indoor rooms in buildings varies greatly. By optimizing the parameters of trench, the average indoor vibration reduction effect can be close to 5dB, and the vibration reduction effect of trench at different positions varies greatly. The increase in trench from 6m to 12m increases the indoor vibration isolation effect.