Abstract

The aim of the present study is to investigate the comparison between the biomechanical behavior of the dental prosthesis composed of three implants replacing successively the premolar and two molars and the dental bridge located between two implants. Both dental structures were subjected to the same masticatory loading (Corono-apical, Linguo-buccal and Disto- mesial). Three-dimensional finite element models of dental structures were developed to determine the stress distribution under simulated applied loads. In this study the biomechanical behavior of prosthetics dental crowns subjected to static loads in contact with the jawbone has been highlighted. Biomechanical simulations indicated that the equivalent stresses in the dental bridge are greater than that produced in the dental prosthesis. The dental bridge can be assimilated to a beam at the embedded ends, subjected to the bending.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.