Abstract
Sintered particle trajectories in the electrostatic precipitator(EP) have been studied numerically in this study. There are live discharge electrodes in the geometry configuration. The discharge electrodes are placed inside the collecting electrodes channel which is 300mm in height, the wire-to-wire distance of each discharge electrode is 500mm. The particle trajectories in the electrostatic precipitator have been investigated considering different inlet flow velocity (1m/s, 1.5 m/s), particle diameter(5μm, 50μm) and applied voltage (56 kV, 63 kV). Results show that it would get better EP efficiency with increasing particle diameter and applied voltage. However, back corona phenomena may be induced if the charged particles are accumulated on the collecting electrode plate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.